중국 전력 변압기 제조 업체

Low-voltageelectrical panel board sizes/ Distribution Panels/Switchgear/distribution box/switchboard

제품 상세 정보:
원래 장소: 중국
브랜드 이름: HENGFENGYOU
인증: ISO IEC CB COC KEMA SNI SABS CCC
모델 번호: MNS
결제 및 배송 조건:
최소 주문 수량: 1
가격: 200-20000/piece
포장 세부 사항: 목제 팩
배달 시간: 30 일
지불 조건: LC T/T
공급 능력: 5000 부분 / 년
지금 연락

상세 정보

하이 라이트:

저전압 개폐기

,

저전압 금속클래드 개폐기

제품 설명

 

                                 Low-voltageelectrical panel board sizes/ Distribution Panels/Switchgear/distribution box/switchboard 0

 

General info

 

MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module through consulting MNS series low voltage switch cabinet of Switzerland ABB Company, and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as control device for various power generation, transmission, distribution, power transfer and power consumption device. It is widely used in low voltage distribution system of various mining enterprise,tall building and hotel, municipal construction etc.

 

Features and Benefits

1.SICO MNS switchgear assembles 4, 2 or 1 drawer units in the space of 8E height, or 1 unit in 16E or 24E. SICO GCS switchgear drawers are divided into 1/2, 1, 2, 3 units

2.Breaker compartment doors have no ventilation openings, thus protecting operators from hot ionized gases vented by the breaker during circuit interruption.

3.A superior bus system offers different levels of protection. Insulated and isolated bus makes maintenance procedures touch friendly to reduce the risk of arc flash.

4.True closed-door drawout construction is standard with all SICO GCS, SICO MNS equipment. The breaker compartment doors remain stationary and closed while the breaker is racked out from the connect position, through test, to the disconnect position. Doors are secured with rugged 1/4-turn latches.

5.An easy-to-read metal instrument panel above each circuit breaker holds a variety of control circuit devices, including the RELT switch.

6.Each circuit breaker is located in a completely enclosed ventilated compartment with grounded steel barriers to minimize the possibility of fault communication between compartments.

7.Optional safety shutters protect operators from accidental contact with live conductors when the breaker is withdrawn.

8.Easy access to equipment compartments simplifies maintenance of the breaker cubicle and control circuit elements as well as inspection of the bolted bus connections.

9.A rail-mounted hoist on top of the switchgear provides the means for installing and removing breakers from the equipment. This is a standard feature on NEMA 3R outdoor walk-in construction and optional on indoor construction.

10.Control wires run between compartments in steel riser channels. Customer terminal blocks are located in metal-enclosed wire troughs in the rear cable area. Intercubicle wiring is run in a wireway on top of the switchgear, where interconnection terminal blocks are located.

11.All circuit breakers are equipped with rollers and a guidebar to provide easy and accurate drawout operation.

12.An optional remote racking device reduces the risk of the arc flash hazard by allowing the operator or electrician to move the breaker anywhere between the DISCONNECT and CONNECT positions from outside the arc flash boundary.

13.Optional infrared (IR) scanning windows can be installed in the switchgear rear covers to facilitate the use of IR cameras for thermally scanning cable terminations.

14.SICO GCS, SICO MNS switchgear can be expanded easily to handle increased loading and system changes. Specify a requirement for a fully equipped future breaker to obtain a cubicle that has been set up for additional breaker installation, or add vertical sections without modifications or the use of transition sections.

15.An array of safety interlock and padlocking features are available to accommodate any type of lockout-tagout procedure a customer may have.

16.Optional Power Management: With the proper devices, facility power can be tracked and controlled.

 

Drawing

Low-voltageelectrical panel board sizes/ Distribution Panels/Switchgear/distribution box/switchboard 1

 

 

 

Structural Characteristics:


1. Compact design:
2. High commonality of the structure and flexibility of assembling. The cubicle body is made up of C-type material with modulus 25mm, it meets the requirements of different structural types, protection categories and operation environment.
3. Modular design: different modular units form standard units of protection, operation, transformation, control, regulation, measurement or indication. Users can freely choose them to assemble what they want. More than 200 assembly components can form different projects of frame configurations and drawer units.
4. Safety: using lots of plastic components of high strength preventing-burning to increase safety.
5. High technology: main parameters reach international technology level.
6. Smaller space: Higher level of miniaturization, smaller space to store and transport pre-manufactured components.
7. Easy to be assembled, no need of special complicated tools.

 

 

Details

 

Low-voltageelectrical panel board sizes/ Distribution Panels/Switchgear/distribution box/switchboard 2

 

 

Service conditions

Suitable Altitude: 1000m ~ 4000m
Suitable Temperature: -40℃ ~ +45℃
Relative Humidity: Daily mean ≤95%, monthly mean ≤90%
Gradation of Earthquake Damage: ≤ Level 8

 

 

ATTENTION:


1.The payment term: We accept TT,30% deposit and 70% balance against copy of BL.
2.The delivery time: Usually it will take about 15-20 days.
3.The standard of package: Usually use strong plywood case for protection.
4.The logo: If you have good quantity, it absolute no problem to do OEM.
5.Our market: our products are popular in Indonesia, Philippines, Russia, USA, Middle East and so on. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutual benefit from our cooperation..
6.Warranty: in 12 month since BL date.

 

 

 order instruction:

1. Schematic diagram of main circuit or electrical schematic diagram

2. Arrangement and layout

3. Model, specification and quantity of main components.

4. Incoming and outgoing wire method and cable specification, etc

5. If bus connection is required between the devices, bus connection and height from the ground shall be provided.

6. Other ordering requirements

 

 

Low-voltageelectrical panel board sizes/ Distribution Panels/Switchgear/distribution box/switchboard 3

우리와 연락하기

당신의 메시지에 들어가십시오

너는 이것들에 빠질 수있다.